S.No. | STANDARD | TITLE |
1. | IEC 60137 | Insulated bushings for AC Voltages above 1 kV |
2. | IEC 60076-1 | Power Transformers - General |
3. | IEC 60076-2 | Temperature rise |
4. | IEC 60076 - 3 | Insulation levels, dielectric tests and external clearances in air |
5. | IEC 60076 -5 | Ability to withstand short |
6. | IEC 60076 - 7 | Loading guide for oil immersed transformers |
7. | IEC 60296 | Specification for unused mineral insulating oils for transformers and switchgear |
8. | IEC 60076 - 10 | Determination of transformer and reactor sound levels |
9. | IEC 60437 | Radio Interference Test on High Voltage Insulators |
10. | IEC 296-1969, IEC 76 | Specification for power transformers |
11. | IEC 296-1969 | Bushing for alternating voltage above 1000V |
12. | DIN 42531 to 33 | Specification for Outdoor Bushings. |
13. | ASTM D-1275 | Specification for fittings and accessories for power transformers |
14. | IEC 76 | Guide for loading of oil immersed Transformers |
15. | BS 159:1957 BS 3288 (Part-1):1960 |
Electrical power connector |
16. | IEC 554 | Specification for Insulating Kraft Paper |
17. | IEC 641 | Specification for Insulating Press Board |
18. | ASTM B-233 | Specification for Al Wire rods |
19. | ASTM D-1275 | Manual on Transformer |
20. | ASTM D-202 | Testing of Insulation Papers |
21. | ISO 2063 | Metallic Coatings - Protection of Iron and Steel against Corrosion |
Load | Minimum Duration in Minutes | |
Percentage of Rating |
Ambient Temperature 30°C | Ambient Temperature 40°C |
133 | 240 | 115 |
150 | 98 | 65 |
Voltage Ratio | kVA Rating | Maximum No-Load Losses in Watts | Maximum Load Losses in Watts |
33kV/400/230V |
25 | 85 | 1210 |
50 | 160 | 1440 | |
100 | 310 | 1900 | |
200 | 540 | 2810 |
Voltage Ratio | kVA Rating | Maximum No-Load Losses in Watts | Maximum Load Losses in Watts |
33kV/250V-0-250V |
10 | 25 | 614 |
15 | 40 | 652 | |
25 | 52 | 780 | |
50 | 100 | 1008 |
WINDING | ||
33kV | LV | |
Basic Impulse Level, kV | 170 | - |
Power Frequency, kV | 70 | 3 |
Days in oil | Minimum percentage retention of bursting strength of original value |
10 | 90 |
30 | 75 |
50 | 60 |
180 | 32 |
Length of plate | Deflection |
Upto 750 mm | 5 mm |
751 to 1250 mm | 6 mm |
Type test | Standard |
Test of temperature rise | IEC 60076 -2 |
Lightning Impulse, including Chopped-waves | IEC 60076-3 |
Noise Level Measurement | IEC 60076-10 |
Measurement Winding Insulation | ASTM D202 (Clause 12) |