Polymer Fuse Cutout 24kv 200A

Product Details
Customization: Available
Breaking Capacity: High
Type: Distribution
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
OHSAS18001:2007, ISO 9001: 2015 Certificate, ISO 14001:2015 Certificate
  • Polymer Fuse Cutout 24kv 200A
  • Polymer Fuse Cutout 24kv 200A
  • Polymer Fuse Cutout 24kv 200A
  • Polymer Fuse Cutout 24kv 200A
  • Polymer Fuse Cutout 24kv 200A
  • Polymer Fuse Cutout 24kv 200A
Find Similar Products

Basic Info.

Model NO.
PRW-24/200
Usage
High Voltage
Shape
Circle
Fusing Speed
T K
Fusing Device
Fuse Link
Standard
IEC IEEE
Transport Package
Cartons Pallets Wooden Case
Specification
IEC282-2 IEEEc37-41
Trademark
OEIpower
Origin
China Nanyang
HS Code
85351000
Production Capacity
100000

Product Description


Polymer Fuse Cutout 24kv 200A
Polymer Fuse Cutout 24kv 200A
Polymer Fuse Cutout 24kv 200A
Polymer Fuse Cutout 24kv 200A
Polymer Fuse Cutout 24kv 200A
Polymer Fuse Cutout 24kv 200A
Polymer Fuse Cutout 24kv 200A
Polymer Fuse Cutout 24kv 200A
Polymer Fuse Cutout 24kv 200A
Polymer Fuse Cutout 24kv 200A
Polymer Fuse Cutout 24kv 200A
Polymer Fuse Cutout 24kv 200A
 The Fuse Cutout type OEI was developed to operate in overhead distribution systems rated at 11
kV to 38 kV grounded systems with 100 or 200 A nominal currents.
Especially designed to protect transformers, capacitors, cables or lines.
It is robust construction, made of rigorously tested material, will interrupt all faults under the
most severe conditions, maintaining mechanical and electric characteristics.
The inserts, hardware and structural bolts and nuts are made from heavy galvanized steel.
The Fuse Cutout type OEI can be applied on all three-phase system rated at or below the maximum
operational rating of the cutout.
 
Performance Characteristic
Applied standard IEC60282-2
Catalog number  
Nominal system voltage kV 11
Rated Frequency Hz 50
Rated m aximum(design) voltage 12
Rated Continuous current A-RMS 100
Rated Interrupting current asymmetrical/symmetrical A-RMS 12000/8000
BIL 1.2x50 µs kV-peak 125
Minimum critical impulse flashover voltage(CFO)KV peak 140
Dry withstand voltage kV-RMS 42
Wet withstand voltage kV-RMS 36
Creepage distance to group Min.mm 372
Minimum creepage factor of insulator (Creepage Distance/arcing distance) N/A