OEM High Voltage 36kv Drop out Cutouts Fuses

Product Details
Customization: Available
Breaking Capacity: High
Type: Distribution
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
OHSAS18001:2007, ISO 9001: 2015 Certificate, ISO 14001:2015 Certificate
  • OEM High Voltage 36kv Drop out Cutouts Fuses
  • OEM High Voltage 36kv Drop out Cutouts Fuses
  • OEM High Voltage 36kv Drop out Cutouts Fuses
  • OEM High Voltage 36kv Drop out Cutouts Fuses
  • OEM High Voltage 36kv Drop out Cutouts Fuses
  • OEM High Voltage 36kv Drop out Cutouts Fuses
Find Similar Products

Basic Info.

Model NO.
PRW-36KV
Usage
High Voltage
Shape
Circle
Fusing Speed
T K
Fusing Device
Fuse Link
Standard
IEC IEEE
Creepage Distance
up to 1200mm
Standard Accessories
Insulating Bracket, Disconnector
Discharge Current
10ka
Optional Accessories
Mounting Bracket, Earth Lead
Transport Package
Cartons Pallets Wooden Case
Specification
IEC282-2 IEEEc37-41
Trademark
OEIpower
Origin
China Nanyang
HS Code
85351000
Production Capacity
100000

Packaging & Delivery

Package Size
60.00cm * 50.00cm * 15.00cm
Package Gross Weight
12.000kg

Product Description


OEM High Voltage 36kv Drop out Cutouts Fuses
OEM High Voltage 36kv Drop out Cutouts Fuses
OEM High Voltage 36kv Drop out Cutouts Fuses
OEM High Voltage 36kv Drop out Cutouts Fuses
OEM High Voltage 36kv Drop out Cutouts Fuses
OEM High Voltage 36kv Drop out Cutouts Fuses
OEM High Voltage 36kv Drop out Cutouts Fuses
CUT-OUT
OEM High Voltage 36kv Drop out Cutouts Fuses




Gama 20 kV a 36 kV
- Circuito Principal 200 A
- Ith 8 kA.
- Montaje Vertical
- Tubo Fusible de 100 A
- Norma CEI 282-2
- Tubo Fusible compatible con los
estándar norteamericanos.
- Este modelo permite el montaje
de la Autoválvula directamente
sobre la escuadra de fijación.
- Eslabones fusible:
de 2 Amp. a 100 Amp.
- Porcelana de color gris, efecto
Antivandálico.
-- Montaje sencillo gracias a sus
tornillos de fijación anti-giro.
- No es necesaria ninguna
herramienta para cambiar el
eslabón
La base cortacircuitos en "V" monta aisladores de columna con
armaduras metálicas externas y línea de fuga en función de los niveles
de contaminación I-III-IV asignados.
Su diseño permite el accionamiento por pértiga desde una posición mas
cómoda para la maniobra, al conseguir un ángulo de 45º con respecto a
la base de sujección.
Incorpora un tubo fusible con capacidad para eslabones de hasta 100A
, y es totalmente intercambiable con los modelos de una columna y
modelos de otros fabricantes.
El interior del tubo portafusible está constituido por un recubrimiento
vegetal lo que le confiere un poder de extinción superior a otros
modelos (según fabricante).
El Seccionalizador en "V" monta aisladores de columna con
armaduras metálicas externas y línea de fuga en función de los niveles
de contaminación I-III-IV asignados.
Su diseño permite el accionamiento por pértiga desde una posición mas
cómoda para la maniobra, al conseguir un ángulo de 45º con respecto a
la base de sujección.
OEM High Voltage 36kv Drop out Cutouts Fuses
Gama:
15 , 24 y 36 kV
12 - 25 - 40 - 63 -100 - 140 A
Número de Defectos: 1 , 2 (Estándar) , 3.
Tiempo de Regeneración : Min. 30s.
Principales Características :
Dispositivo Autoalimentado. Utilización conjunta con Interruptores automáticos.
Importante reducción en los costes derivados de mano de obra y sustitución de fusible de los Cut-Out
convencionales derivados de fallos transitorios, ocasionados por tormentas eléctricas , accidentes
vegetales , etc...
Ausencia de Arcos y desgaste en los contactos.
Reutilización del equipo tras su rearme manual y acoplamiento en su base.
TYPE "OEI" "PRW" STANDARD CUTOUT DISTRIBUTION TECHNICAL SPECIFICATION
The Fuse Cutout type DHE was developed to operate in overhead distribution systems rated at 12-15 kV and 15-27,kV or 27-38 kV grounded systems with 100 or 200 A nominal currents.
Especially designed to protect transformers, capacitors, cables or lines.
It is robust construction, made of rigorously tested material, will interrupt all faults under the
most severe conditions, maintaining mechanical and electric characteristics.
The inserts, hardware and structural bolts and nuts are made from heavy galvanized steel.
The Fuse Cutout type OEI PRW can be applied on all three-phase system rated at or below the maximum operational rating of the cutout. In highly polluted environments or environments with high levels of salinity, a cutout may be used with a higher nominal rating than
that of the system where it is being installed, where the insulator will have a greater leakage distance to ground, allowing for
increased safety against discharge. For an even better protection against abrasions, the hardware may be supplied in stainless
OEM High Voltage 36kv Drop out Cutouts Fuses
steel. The fuse cutout type OEI PRW has attachment hooks in aluminum.
The Fuseholder has a stainless steel flipper, which associated with a spring doesn't allow the fuse link to be subject to traction
forces of over 3 Kgf, especially during closing. This me chanism also allows for high speed fuse link separation. The fuse cutout
type OEI PRW allows for the insertion of the fuse tube in a precise man ner and always in perfect alignment, due to the large distance
between the grunion pocket. Lower contact, silver-to-silver, provide du el current path, independent of hinge pivot. Stainless-steel
back-up springs prevent arcing when tube rises in hinge during recoil. The fuse cutout type OEI PRW may be transformed into a DICONNECT up to 300 A, by simply changing the fuse tube for an electrolytic copper blade.
The DHE Fuse Cutouts conform to ANSI and IEC standards, with independent tests performed At:
CPRI Always use quality fuse links. Only they can assure excellent performance.
 Lightning Arrestors
 
11kV
 
 
 
No. DETAIL UNITS DATA

 
Type
 
11kV gapless type metal oxide surge
arrester - Distribution class
1. Nominal  system  voltage kV 11
2. Highest system voltage kV 12
3. Basic Insulation Leve (BIL) kV 95

 
 
3.   Ratings and type of surge arrester

 

 
4. Specification to which surge arrester complies
 
IEC
60099-4
5. Rated voltage of surge arrester kV 10
6. Nominal, 8/20 µs, discharge current rating of
surge arrester
kA 10
7. Maximum continuous operating voltage of
surge arrester
kV 7.3
8. Gapless or gapped type metal-oxide surge
arrester

 
Gapless
9. Material of insulation
 
High temperature vulcanised silicon
rubber
10. Rated frequency of surge arrester Hz 50
11. Design altitude of surge arrester (above sea
level)
m 1 400m
12. Design ambient temperature of surge arrester oC -1 to40
13. Specific creepage distance of surge arrester .mm/kV 25

 
Automatic earth lead disconnectors
requirements

 

 
14. Automatic earth lead disconnectors to be fitted Yes/No YES
 

 
 
15. Corrosion protection of metal and alloy parts:
galvanising specification and/or stainless steel grade

 
To SABS 763, 316

 
Tests
 

 
16. Previous type test results/certificate to be
provided with bid
Yes/No Yes
17. Routine test results/certificate to be provided
on delivery
Yes/No Yes
18. Drawing showing dimensions of the arrestor to
be provided with the bid
Yes/No Yes
19. Minimum one minute wet power frequency
withstand voltage of external insulation of surge arrester housing
kV 28
20. Maximum steep current impulse residual
voltage for a 10 kA, 1/20 µs, discharge current
kV 50
21. Maximum lightning impulse residual voltage
for a 10 kA, 8/20 µs, discharge current
kV 40
22. Lightning, 1,2/50 µs, impulse withstand level
of external insulation of surge arrester housing
kV 95
23. Line discharge class rating
 
1
24. Long duration current, 2 000 µs, impulse
withstand
A 250 A
25. High current, 4/10 µs, impulse withstand kA 100 kA
26. Automatic earth lead disconnector to be tested
in accordance with IEC 60099-4
Yes/No Yes
 
 
 
 
 
 
 
 
 
 
 
33kV
 
 
 
 
S/N TECHNICAL DETAILS UNITS DATA
1. Type
 
33kV gapless type metal
oxide surge arrester -
Distribution class
2. Nominal  system  voltage kV 33
3. Highest system voltage kV 36
4. Power frequency Hz 50
5. Basic Insulation Leve (BIL) kV 170

 
 
3.   Ratings and type of surge arrester

 

 
6. Specification to which surge arrester complies
 
IEC 60099
7. Rated voltage of surge arrester kV 29
8. Nominal, 8/20 µs, discharge current rating of surge arrester kA 10
9. Maximum continuous operating voltage of surge arrester kV 22
10. Gapless or gapped type metal-oxide surge arrester
 
Gapless
11. Insulation Material
 
Silicon rubber
12. Cantilever strength of surge arrester Nm 300
13. Rated frequency of surge arrester Hz 50
14. Design altitude of surge arrester (above sea level) m 1 400m
15. Design ambient temperature of surge arrester oC -1 to 40
16. Minimum phase-to-ground specific creepage distance of
surge arrester
.mm/kV 25

 
Automatic earth lead disconnectors requirements
 

 
17. Automatic earth lead disconnectors fitted Yes/No Yes
18. Corrosion protection of metal and alloy parts: galvanising
 
To  SABS 763, 316

 

 

 

 

 
 

 
 

 
specification and/or stainless steel grade
 

 

 
Tests
 

 
19. Previous Type Test reports/certificate  from recognized
authority to be provided with bid
Yes/No Yes
20. Minimum one minute wet power frequency withstand
voltage of external insulation of surge arrester housing
kV 70
21. Maximum steep current impulse residual voltage for a 10
kA, 1/20 µs, discharge current
kV 99.7
22. Maximum lightning impulse residual voltage for a 10 kA,
8/20 µs, discharge current
kV 91.8
23. Lightning, 1,2/50 µs, impulse withstand level of external
insulation of surge arrester housing
kV 170
24. Line discharge class rating Class 1
25. Long duration current, 2 000 µs, impulse withstand A 250 A
26. High current, 4/10 µs, impulse withstand kA 100 kA
27. Is the automatic earth lead disconnector tested in accordance
with IEC 60099-4?
Yes/No Yes
 
 
 
 
66kV
 
 
 
 
S/N TECHNICAL DETAILS UNITS DATA
1. Description
 
Station type lightning arrestor
complete with steel support structures.
2. Type
 
Zinc oxide gapless lightning
arrestor

 
System parameters
 

 
3. Nominal  system  voltage kV 66
4. Highest system voltage kV 72.5
5. Power frequency Hz 50
6. Type of system earthing
 
Effective/Non effective
7. Type of arrestor connection to system
 
Line to ground

 
 
3.   Ratings and type of surge arrester

 

 
8. Rated voltage of surge arrester kV rms 54
9. Nominal, 8/20 µs, discharge current rating of surge arrester kA peak 10
10. Maximum continuous operating voltage of surge arrester kV 43
11. Minimum one minute wet power frequency withstand voltage kVrms 140
 
 
151
 
 
 
 

 
of external insulation of surge arrester housing
 

 
12. Maximum steep current impulse residual voltage for a 2 kA,
30/60 µs, discharge current
kVpeak 104
13. Maximum lightning impulse residual voltage for a 10 kA, 8/20
µs, discharge current
kVpeak 127
14. Minimum lightning, 1,2/50 µs, impulse withstand level of
external insulation of surge arrester housing

 
325
15. Line discharge class rating
 
2
16. Lighting arrestor counter, leakage current meter and their
accessories to be provided
Yes/No Yes
17. Gapless or gapped type metal-oxide surge arrester
 
Gapless
18. Insulation Material
 
Porcelain
19. Cantilever strength of surge arrester Nm 3000
20. Rated frequency of surge arrester Hz 50
21. Maximum angle from vertical at which surge arrester is fully
functional
Deg 45
22. Design altitude of surge arrester (above sea level) m 1400 m
23. Design ambient temperature of surge arrester oC -1 to 40
24. Humidity % 85
25. Specific phase-to-ground creepage of surge arrester .mm/kV 25
26. Corrosion protection of metal and alloy parts: galvanising
specification and/or stainless steel grade

 
to SABS 763 or 316 stainless
steel
27. Previous type test results/certificate to be provided with bid Yes/No Yes
28. Design drawings showing dimensions including foundations
and brochures to be provided with bid
Yes/No Yes
29. Quality Assurance certification to be provided with the bid Yes/No Yes
30. Routine test results/certificate to be provided on delivery Yes/No Yes
31. Galvanized steel support structures complete with bolts &
washers to be provided on delivery
Yes/No Yes
32. Applicable standard
 
IEC60099

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now