Pelican Hot-Plugging Clamp E

Product Details
Customization: Available
Transport Package: Cartons Pallets Wooden Case
Specification: IEC IEEE
Still deciding? Get samples of US$ 20/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
OHSAS18001:2007, ISO 9001: 2015 Certificate, ISO 14001:2015 Certificate
  • Pelican Hot-Plugging Clamp E
  • Pelican Hot-Plugging Clamp E
  • Pelican Hot-Plugging Clamp E
  • Pelican Hot-Plugging Clamp E
Find Similar Products

Basic Info.

Model NO.
Y2-3
Trademark
OEIpower
Origin
China Nanyang
HS Code
7616991090
Production Capacity
100000

Product Description

Pelican Hot-Plugging Clamp EPelican Hot-Plugging Clamp EPelican Hot-Plugging Clamp EPelican Hot-Plugging Clamp ERemovable connector for footboard
Hotline clamp 
 
6 Rules   ANSI C119-4, ASTM 153
7 Quality certificate   ISO 9001
8 DN-DS certificate   Attach acceptance certificate and 
homologation 
9 Raw material of the body   Specify
10 Galvanized   Hot dip
  characteristics    
11 Main range AWG 2/0 -2
12 Connection diameter 
maximum derivation 
  1 (13/32)
13 Minimum derivation connection diameter   4 (3/16)
14 DN-DS certificate   Attach acceptance certificate and 
homologation 
15 Identification mark   Each connector must be marked on the body with the manufacturer's symbol, catalog number, application conductor ranges and number of die to be occupied with the hydraulic tool for its 
installation 
Type H aluminum compression connector, 2 - 6
AL 2 - 6 ACSR.
4 Connector name   Type H aluminum compression connector, 2 - 6
AL 2 - 6 ACSR.
5 Raw material   The connectors must be made of alloy 
pressure-stretched aluminum, with a high degree of hardness Rockwell RH30, or a ductile aluminum high conductivity alloy 1100-0, which is a highly pure aluminum 
6 Rules   ANSI C119.4
7 Quality certificate   ISO-9001 or recent
8 Finish   The surface of the connectors should be smooth 
, free of astilaldura or imperfections 
9 Shape   H
10 Main Calibres Range ACSR # 2
11 Secondary Calibers Range ACSR # 2
12 High inch(mm) 1.12 (31)
13 Long inch(mm) 1.5 (29)
14 Width inch(mm) 0.7 (18)
15 External Comma   The external part of the connector should be placed 
with a bath of metallic stamp, in order to 
prevent environmental corrosion to moisture and air on the contact surface 
16 Inhibitory compound   Each connector must present in the slot a 
Composite of the oxide and galvanic corrosion 
17 Identification mark   Each connector should be marked with the 
manufacturer's symbol, catalog number, 
Application driver range, number of die to occupy. When this information is not possible to present in the body of the connector, it will be printed on the connector bag except for the manufacturer's brand and name, which must necessarily be indicated on the body of the connector 
18 Packaging   Each connector should be individually 
packed in a high plastic bag 
resistance duly sealed for intempere, in order to prevent external agents from damaging it and causing premature oxidation. 

for cable #2

 
6 Rules   ANSI C119-4, ASTM 153
7 Quality certificate   ISO 9001
8 DN-DS certificate   Attach acceptance certificate and 
homologation 
9 Raw material of the body   Specify
10 Galvanized   Hot dip
  characteristics    
11 Main range AWG 2/0 -2
12 Connection diameter 
maximum derivation 
  1 (13/32)
13 Minimum derivation connection diameter   4 (3/16)
14 DN-DS certificate   Attach acceptance certificate and 
homologation 
15 Identification mark   Each connector must be marked on the body with the manufacturer's symbol, catalog number, application conductor ranges and number of die to be occupied with the hydraulic tool for its 
installation 

Pelican Hot-Plugging Clamp E
 
4 Connector name   Aluminum compression connector 
type H, 1/0 - 3 AL 2 - 6 ACSR. 
5 Raw material   The connectors must be made of alloy 
pressure-cast aluminum, with a high degree of Rockwell RH30 hardness, or a 1100-0 high conductivity aluminum ductile alloy, which is a highly pure aluminum 
6 Rules   ANSI C119.4
7 Quality certificate   ISO-9001 or recent
8 Finish   The surface of the connectors should be smooth 
, free of astilaldura or imperfections 
9 Shape   H
10 Main Calibres Range ACSR 1 / 0-3
11 Secondary Calibers Range ACSR 2-6
12 High inch(mm) 1.2 (30)
13 Long inch(mm) 1.75 (44)
14 Width inch(mm) 0.70 (18)
15 External Comma   The external part of the connector should be placed 
with a bath of metallic stamp, in order to 
prevent environmental corrosion to moisture and air on the contact surface 
16 Inhibitory compound   Each connector must present in the slot a 
Composite of the oxide and galvanic corrosion 
17 Identification mark   Each connector should be marked with the 
manufacturer's symbol, catalog number, 
Application driver range, number of die to occupy. When this information is not possible to present in the body of the connector, it will be printed on the connector bag except for the manufacturer's brand and name, which must necessarily be indicated on the body of the connector 
18 Packaging   Each connector should be individually 
packed in a high plastic bag 
resistance duly sealed for intempere, in order to prevent external agents from damaging it and causing premature oxidation. 

 
4 Material name   Aluminum compression connector 
Type H, 3/0 AL 3/0 ACSR 
5 Raw material   Bimetallic aluminum pressure stretched, with high degree of hardness Rockwell RH30, high conductivity 1100-0
6 Rules   ANSI C119.4, UL486 A
7 Quality certificate   ISO 9001
8 Kind   H
9 Main gauges   3/0 - 4/0 ACSR
10 Caliber derivation   3/0 - 4/0 ACSR
11 Type of conductor to be connected   Aluminum, copper and ACSR
12 Slot with rust inhibitor   Yes
13 Height approx. inch(mm) 1-1 / 2 (38.10)
  Length approx. inch(mm) 2- 1/2 (63.5)
14 Width approx. inch(mm) 6/7 (21.77)
15 External Comma   The external part of the connector should be placed 
with a bath of metallic stamp, in order to 
prevent environmental corrosion to moisture and air on the contact surface 
16 Inhibitory compound   Each connector must present in the slot a 
Composite of the oxide and galvanic corrosion 
17 Identification mark   Each connector should be marked with the 
manufacturer's symbol, catalog number, 
Application driver range, number of die to occupy. When this information is not possible to present in the body of the connector, it will be printed on the connector bag except for the manufacturer's brand and name, which must necessarily be indicated on the body of the connector 
18 Packaging   Each connector should be individually 
packed in a high plastic bag 
resistance duly sealed for intempere, in order to prevent external agents from damaging it and causing premature oxidation. 


kV to 38 kV grounded systems with 100 or 200 A nominal currents.

 
4 Connector name   Compression connector grounding pin for cable # 2
5 Raw material   Body: Electrolytic copper manufactured by extrusion, high resistance- With inhibitor
6 Driver to press   Copper
7 Driver to connect on the pike 
grounding 
AWG 2
8 Applied standards   ANSI C 119.4, IEEE837
9 Quality certificate   ANSI C 119.4, IEEE837
10 Main admissible diameter inch(mm) 5/8 (15.8)
11 Permissible diameter inch(mm) 0.29 to 0.23 (7.4 to 5.8)
12 DN-DS certificate   Attach acceptance certificate and 
homologation 
13 Identification mark   Each connector should be 
marked on the body with the 
manufacturer symbol, catalog number, application driver ranges and die number to occupy with the hydraulic tool for installation 
14 Packing   The connectors should be 
in a package that indicates in 
its exterior the range of application and prevent external agents from damaging it and causing premature oxidation 


Pelican Hot-Plugging Clamp E
Especially designed to protect transformers, capacitors, cables or lines.
It is robust construction, made of rigorously tested material, will interrupt all faults under the
most severe conditions, maintaining mechanical and electric characteristics.
he inserts, hardware and structural bolts and nuts are made from heavy galvanized steel.
The Fuse Cutout type OEI can be applied on all three-phase system rated at or below the maximum
operational rating of the cutout.
Product D  Bracket
Test Items Test Content Test Result  
Sample
1
Sample 
2
Sample 
3
Sample
4
Sample
5
Remarks
Visual  Inspection Crack 1)      Passed Mark"√"
2)  Not Passed Mark"×"
Test Conclusion:
Stoma Trachoma
Fins
Burr
Galvanizing thickness μm 1)      Passed Mark"√"
2)      Not Passed Mark"×":
Test Conclusion:
Mechanical Characteristics Mechanical Load 1)Passed Mark"√"
2)Not Passed Mark"×"
Test Conclusion:
Inspector Date:  02. March,2011                        Approved: