Model NO.
s-15
Number of Poles
Three Pole
Grounding
Single Ground
Series
Three
Run
Turn the Horizontal
Common Model
Ist
Structure of Operating
Manual
Certification
IEC IEEE
Brand
Oei Power
Transport Package
Cartons Pallets Wooden Case
Specification
IEC62271-102
Trademark
OEIpower
Origin
China Nanyang
HS Code
8535309000
Production Capacity
100000

Product Description


The Gang operated Air break switches are meant for outdoor application and are suitable for horizontal or
vertical mounting. They are designed for satisfactory performance in harsh atmospheric conditions of
high/low temperatures & humidity. Their primary function is to isolate a 11 kV, 3 Phase network. Asiatic
manufactures the Air break switches in both Porcelain & Silicone rubber versions.
Features
4Single break type with 2 or 3 post insulators per pole depending on requirements of the
customers.
4Can be used for single or three phase applications.
4Robust sturdy design with bottom MS channel of
adequate dimensions which imparts requisite strength.
4Self lubricating central bush bearing in 2 or 3 insulator design of air break switches allows easy
operation.
4Copper contacts are made of ETP grade high conductivity copper and are spring loaded for
adequate contact pressure. The contacts are duly
plated to improve resistance to corrosion and
offers a low resistance current path.
4The Post insulators are available in Porcelain and  Silicone Rubber with large creepage distance
suitable for heavily polluted atmosphere and
meets the stringent requirements of IS/IEC
standards.
4All MS parts and Hardware are duly hot dip galvanized as per standard specifications which
imparts long life to the switch.
4In 3 insulator design, tin plated braided Copper
wire of adequate cross section is provided as per
rating of the GOAB switch and depending upon
customer requirements.
4The Isolator is capable of withstanding the electrical & mechanical stresses induced during unlikely event of short circuits.
4The operation is either hook operated in silicone version through an insulated operating stick or
sturdy operating mechanism is provided allowing easy operation 6 meters above ground level with
simultaneous operation of all the three poles making perfect electrical contact.
4 Mechanical locking facility is provided for closed & open positions as required.
Type test
The GOAB switch in both Porcelain & Silicone Rubber
insulators have been extensively type tested at CPRI - a
laboratory of International repute as per IEC 62271-102 respectively for the following
Tests:
Short Time & Peak withstand Current.
Mechanical Endurance Test.
Lightning Impulse Voltage withstand Test.
High Voltage Dry & Wet Power Frequency Test

 
 
 SOLID LINKS 11KV
 
 
 
 
 
N/O DETAIL   DATA
1 Description   Solid link assembly complete with link
rated at 200A and mounting bracket to PIESA 002. (See Figure 1  to Figure 12 below)
2 System conditions of service
 
 
 
a) nominal Voltage (Un) r.m.s
 
 
 
 
kV
 
 
 
 
11
b) maximum system voltage (Um) r.m.s KV 12
c) earthing   Effective & non effective
d) Frequency Hz 50
3 Site conditions of service
a) altitude
 
m
 
1400
b) Operating Ambient temperature °C -1 to 40
c) Humidity % 85
4 Rating    
a) Nominal voltage kV 11
b) Rated current Solid link  
A
 
200
 
Cut out base
 
A
 
200
5 Electrical components    
a) Insulator material specification   Porcelain
Dielectric strength    
Lightning  impulse withstand (1.2/50) kV 95
Power frequency wet withstand voltage
r.m.s
kV 28
6 Specific creepage distance mm/kV 25



 
 
7 General information to be provided
with bid:
Drawings and brochures showing outline and general arrangement
 
 
 
 
Yes/No
 
 
 
 
Yes
  b) Detailed drawings of all items
showing critical tolerances to be provided with bid
Yes/No Yes
8 Previous Type test report/certificate on
complete solid link assembly to be provided with bid
 
Yes/No
 
Yes
10 Routine tests (acceptance tests on
sample
Product) to be provided on delivery
Yes/No Yes
11 Applicable standard   PIESA 002
12 Other applicable standards   NRS 035
SABS IEC 60282-2
SABS IEC 60186
BS 137 part 2


 
 


TRI-LINKS
 
 
 
Lot 3-(a) 11kV with interrupters
 
 
 
N/O DETAIL   DATA
1 TYPE   11kV pre-assembled gang
operated overhead line load break switch complete with expulsion interrupters
2 Mounting configuration   Horizontal
3 Mode of operation   Manually operated pole
mounted linking rod and handle with locking facilities
  a) nominal Voltage (Un) r.m.s kV 11
b) maximum voltage (Um) r.m.s KV 12
c) earthing   Effective & non effective
d) Frequency Hz 50
e) rated current Amp 400
f) Fault closing capacity kA 12.5
4 Site conditions of service
a) altitude
 
metres
 
1400
b) Operating Ambient temperature  
°C
 
-1 to +40
c) Relative humidity % 85
5 Electrical components    
a) Insulator material specification   High Temperature Vulcanised
Silicon rubber
b) Cross arm and operating controls materials   Hot dip galvanized steel to
SAN760
Dielectric strength    
Lightning  impulse withstand (1.2/50) kV 95



 
 
  Power frequency wet withstand voltage r.m.s KV 28
  Short time current rating -1sec kA 12.5
6 creepage distance mm/kV 25
7 General information to be provided with bid:
Drawings and brochures showing
Outline and general arrangement
 
 
 
Yes/No
 
 
 
Yes
8 Previous Type test report/certificate on complete
assembly to be provided with bid
Yes/No Yes.
9 Routine tests (acceptance tests on sample
 
Product) to be provided on delivery.
Yes/No Yes
10 Applicable standards   IEC62271


 
 
FURTHER REQUIREMENTS:
 
Water shall not be able to accumulate on any part of the equipment nor shall any feature introduce moisture into any component.
The design shall incorporate all reasonable precautions and provisions for the safety of personnel concerned with the operation and maintenance of the same.
The current path shall be such that load current shall only flow through high conductive materials such as copper and its alloys. Load current shall not be permitted to flow through ferrous components, springs, or spring-loaded mechanisms.
All load current paths shall be so designed that the relevant parts of the switch are capable of carrying the specified rated current without exceeding the permitted temperature rise.
 
 
 
SUPPLIMENTARY NOTES
 
Suppliers should give sufficient information including drawings (which must be brief, clear and to the point) on how their switch designs addresses these requirements. Further, Suppliers may offer better alternatives that are of cost benefits to customer, It is therefore imperative that schedule "B" is completed by the tenderer. Any deviations/modifications/alternatives specification must be listed in schedule "C.
 
 

 
 
 
 
33kV with interrupters
 
 
 
N/O DETAIL   DATA
1 TYPE   33kV pre-assembled gang
operated overhead line load break switch complete with expulsion interrupters
2 Mounting configuration   Horizontal
3 Mode of operation   Manually operated pole
mounted linking rod and handle with locking facilities
  a) nominal Voltage (Un) r.m.s kV 33
b) maximum voltage (Um) r.m.s KV 36
c) earthing   Effective & non effective
d) Frequency Hz 50
e) rated current Amp 200
f) Fault closing capacity kA 12.5
4 Site conditions of service
a) altitude
 
metres
 
1400
b) Operating Ambient temperature  
°C
 
-1 to +40
c) Relative humidity % 85
5 Electrical components    
a) Insulator material specification   High Temperature Vulcanised
Silicon rubber
b) Cross arm and operating controls materials   Hot dip galvanized steel to
SAN760
Dielectric strength    
Lightning  impulse withstand (1.2/50) kV 170
Power frequency wet withstand voltage r.m.s KV 70
  Short time current rating -1sec kA 12.5
6 creepage distance mm/kV 25
7 General information to be provided with bid:    



 
 
  Drawings and brochures showing
Outline and general arrangement
 
Yes/No
 
Yes
8 Previous Type test report/certificate on complete
assembly to be provided with bid
Yes/No Yes
9 Routine tests (acceptance tests on sample
 
Product) to be provided on delivery
Yes/No Yes
10 Applicable standards   IEC62271


 
 
FURTHER REQUIREMENTS:
 
Water shall not be able to accumulate on any part of the equipment nor shall any feature introduce moisture into any component.
The design shall incorporate all reasonable precautions and provisions for the safety of personnel concerned with the operation and maintenance of the same.
The current path shall be such that load current shall only flow through high conductive materials such as copper and its alloys. Load current shall not be permitted to flow through ferrous components, springs, or spring-loaded mechanisms.
All load current paths shall be so designed that the relevant parts of the switch are capable of carrying the specified rated current without exceeding the permitted temperature rise.
 
 
 
SUPPLIMENTARY NOTES
 
Suppliers should give sufficient information including drawings (which must be brief, clear and to the point) on how their switch designs addresses these requirements. Further, Suppliers may offer better alternatives that are of cost benefits to custoemr.
 
 
 

 
 
 
 
11kV without interrupters
 
 
 
 
N/O DETAIL   DATA
1 TYPE   11kV pre-assembled gang
operated overhead line switch without expulsion interrupters (non-load break switch)
2 Mounting configuration   Horizontal
3 Mode of operation   Manually operated pole
mounted linking rod and handle with locking facilities
  a) nominal Voltage (Un) r.m.s kV 11
b) maximum voltage (Um) r.m.s KV 12
c) earthing   Effective & non effective
d) Frequency Hz 50
e) rated current Amp 400
4 Site conditions of service
a) altitude
 
metres
 
1400
b) Operating Ambient temperature  
°C
 
-1 to +40
c) Relative humidity % 85
5 Electrical components    
a) Insulator material specification   High Temperature Vulcanised
Silicon rubber
b) Cross arm and operating controls materials   Hot dip galvanized steel to
SAN760
Dielectric strength    
Lightning  impulse withstand (1.2/50) kV 95
Power frequency wet withstand voltage r.m.s KV 28
  Short time current rating -1sec kA 12.5
6 creepage distance mm/kV 25
7 General information to be provided with bid:    



 
 
  Drawing and brochures showing
Outline and general arrangement
 
Yes/No
 
Yes
8 Previous Type test report/certificate on complete
assembly to be provided with bid
Yes/No Yes
9 Routine tests (acceptance tests on sample
 
Product) to be provided on delivery
Yes/No Yes
10 Applicable standards   IEC62271


 
 
FURTHER REQUIREMENTS:
 
Water shall not be able to accumulate on any part of the equipment nor shall any feature introduce moisture into any component.
The design shall incorporate all reasonable precautions and provisions for the safety of personnel concerned with the operation and maintenance of the same.
The current path shall be such that load current shall only flow through high conductive materials such as copper and its alloys. Load current shall not be permitted to flow through ferrous components, springs, or spring-loaded mechanisms.
All load current paths shall be so designed that the relevant parts of the switch are capable of carrying the specified rated current without exceeding the permitted temperature rise.
 
 
 
SUPPLIMENTARY NOTES
 
Suppliers should give sufficient information including drawings (which must be brief, clear and to the point) on how their switch designs addresses these requirements. Further, Suppliers may offer better alternatives that are of cost benefits to
 

 
 
 
 
 
33kV without interrupters
 
 
N/O DETAIL   DATA
1 TYPE   33kV pre-assembled gang
operated overhead line switch without expulsion interrupters (non-load break switch)
2 Mounting configuration   Horizontal
3 Mode of operation   Manually operated pole
mounted linking rod and handle with locking facilities
  a) nominal Voltage (Un) r.m.s kV 33
b) maximum voltage (Um) r.m.s KV 36
c) earthing   Effective & non effective
d) Frequency Hz 50
e) rated current Amp 200
4 Site conditions of service
a) altitude
 
metres
 
1400
b) Operating Ambient temperature  
°C
 
-1 to +40
c) Relative humidity % 85
5 Electrical components    
a) Insulator material specification   High Temperature Vulcanised
Silicon rubber
b) Cross arm and operating controls materials   Hot dip galvanized steel to
SAN760
Dielectric strength    
Lightning  impulse withstand (1.2/50) kV 170
Power frequency wet withstand voltage r.m.s KV 70
  Short time current rating -1sec kA 12.5
6 creepage distance mm/kV 25
7 General information to be provided with bid:    



 
 
  Drawing and brochures showing
Outline and general arrangement
 
Yes/No
 
Yes
8 Previous Type test report/certificate on complete
assembly to be provided with bid
Yes/No Yes
9 Routine tests (acceptance tests on sample
 
Product) to be provided on delivery
Yes/No Yes
10 Applicable standards   IEC62271


 
 
FURTHER REQUIREMENTS:
 
Water shall not be able to accumulate on any part of the equipment nor shall any feature introduce moisture into any component.
The design shall incorporate all reasonable precautions and provisions for the safety of personnel concerned with the operation and maintenance of the same.
The current path shall be such that load current shall only flow through high conductive materials such as copper and its alloys. Load current shall not be permitted to flow through ferrous components, springs, or spring-loaded mechanisms.
All load current paths shall be so designed that the relevant parts of the switch are capable of carrying the specified rated current without exceeding the permitted temperature rise.
 
 
 
SUPPLIMENTARY NOTES
 
Suppliers should give sufficient information including drawings (which must be brief, clear and to the point) on how their switch designs addresses these requirements. Further, Suppliers may offer better alternatives that are of cost benefits to.
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
Management System Certification
OHSAS18001:2007, ISO 9001: 2015 Certificate, ISO 14001:2015 Certificate