60kv Capacators

Type: Distribution
12: Kv
24: Kv
36: Kv
Transport Package: Cartons Pallets Wooden Case
Specification: IEC IEEE
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Trademark
OEIpower
Origin
China Nanyang
HS Code
8532100000
Production Capacity
100000

Product Description

60kv Capacators60kv Capacators60kv Capacators60kv CapacatorsHigh-voltage shunt capacitor
 
Main purpose and scope of application
High-voltage shunt capacitors are mainly used in 50H 60Hz ac power system to improve the power
factor.Reduce reactive power loss, improve voltage quality, give full play to power generation, power supply
equipment efficiency.It is the energy-saving product recommended by the state.
This product conforms to: national standard GB/ t11024.1-2010 (our company is the main drafting unit of this
standard)
The working conditions
1. The altitude shall not exceed 1000m, the ambient temperature shall be -40/B, and the maximum
temperature of category B shall be +45S
2. There is no violent vibration, no harmful gas and steam, no conductive or explosive dust in the installation
site.
3. The capacitor shall be operated under good ventilation conditions and shall not be operated under closed
and unventilated conditions.
4. Soft wire shall be used for connection of electric alligator, and the outlet circuit shall be in good contact.High-voltage shunt capacitor
Structural features
1. The capacitor is composed of a box shell and a core. The box shell is made of steel sheet sealed welding. The box shell is welded with a cable outlet porcelain sleeve. The
60kv Capacators
sides of the box wall are welded with a mounting bracket.
2. The capacitor core is formed by laminating several components and insulation parts, and the components are formed by winding and flattening the two aluminum foil
intermediate film paper composite media or full-film media as polar plates. The components in the core are connected in a certain series and parallel manner to meet the
requirements of different voltages and capacities.
3. A capacitor with an internal fuse. Each element has a fuse in series. When a certain element breaks down, the intact element connected in parallel with it discharges it, and
the wire quickly fuses in milliseconds, which will cause a failure The component is cut off, so that the capacitor continues to run.
4.Three-phase capacitors are star-connected
5. The liquid medium in the capacitor is used to impregnate the solid medium and fill the interior of the capacitor. It has excellent electrical and physical properties and has good
compatibility with other materials in the capacitor.
The main technical parameters
1. Rated voltage: 6.3kV, 6.6kV, 6.6 "3kV, 10.5kV, 11kV, 11 but kV, 12kV, 12 / j3kV, 19kV
2. Rated capacity: 30 ~ 334kvar, other voltage levels and Rongxing can be specially ordered.
3. Capacity tolerance: -5- + 10%
4. Loss angle tangent: film paper composite media tanδ≤0.08%, full film media tanδ≤0.05%
5. withstand voltage: capacitors should be able to withstand AC 2.15 times or DC 4.3 times the rated voltage, without breakdown or flashover for 10s.
Insulation level: 6kV level 30kV, 10kV level 42kV AC test lasted 1 minute without breakdown or flashover.
6. Self-discharge performance: The capacitor equipped with a discharge resistor inside, the residual voltage drops from the peak 2UN peak to less than 75V within 10min after
power failure.
7. the maximum allowable overvoltage: 1.1 times the rated voltage, not more than 8 hours per 24 hours, 1.15 times the rated voltage, not more than 30 minutes per 24 hours, 1.2
times the rated voltage not more than 5 minutes, 1.3 times the rated No more than 1 minute at voltage
8. Maximum allowable current: Allow the current to run under 1.3 times the rated current, and consider the over-voltage during the transition overcurrent, the positive deviation
of the capacitor and the influence of harmonics must not exceed 1.43 times the rated current.
9. Compliance with standards: The product complies with the national standard GB / T11024.1 -2010 and the international standard IEC60871 -1: 2005.
 
Main specifications
 
Model
Voltage(kV)
capacity(kvar)
capacitance( F)
Current ln(A)
BFM12-100-1W
12 100 2.2 8.33
BFM12-150-1W 12 150 3.3 12.5
BFF12-100-3W 12 100 2.2 4.8
BFF33-150-3W 33 150 3.3 7.2
BFM24-100-3W 24 100 2.2 4.8
BFM38-150-3W 38 150 3.2 7.2
 
 
 
Note: Other special specifications and models are supplied according to user requirements
Order and use instructions
1. The selection of the rated voltage of the capacitor must be based on the network voltage. Considering that the capacitor input will increase the voltage, when selecting
the rated voltage of the capacitor, it is at least 5% higher than the network voltage. When there is a reactor in series in the capacitor circuit, the capacitor's The terminal
voltage will increase correspondingly with the reactance rate of the reactor in the string, so when selecting the rated voltage of the capacitor, it should be determined after
calculation based on the reactance rate of the reactor in series.
2. A capacitor is a low-impedance channel of harmonics. Under the harmonics, a large amount of harmonics will be injected into the capacitor to make the capacitor
overcurrent or overvoltage. In addition, the capacitor will amplify the harmonic and even cause resonance, endangering the safety of the power grid and making the
capacitor The life is greatly shortened. Therefore, in the case of large harmonics, the capacitor must be used in series with a reactor that suppresses harmonics.
3. The inrush current when the capacitor is closed can reach hundreds of times of the rated current of the capacitor. Therefore, the switch for switching capacitors should
be a switch without heavy breakdown. In order to suppress the inrush current, the reactor can be connected in series to suppress the inrush current.
4. The internal capacitor equipped with a discharge resistor can be reduced from the peak value of the rated voltage to less than 75V within 10 minutes after disconnecting
from the power supply. If it is required to reduce the peak value of the rated voltage to less than 50V within 5 minutes after the power is disconnected, Indicate when
ordering.
5. For capacitors used for line compensation, it is advisable to install 150 ~ 200kvar in one place, and be careful not to install the capacitor on the same stage as the
transformer. Do not use the same group of drops to prevent the possibility of ferromagnetic resonance caused by the incomplete phase operation of the line. Damage to
capacitors and transformers due to over-current, over-voltage.
6. Select a zinc oxide lightning arrester to protect the operating over-voltage. A zinc oxide lightning arrester dedicated to capacitors should be used, and it is best to be
installed between the capacitor poles.
7. Quick-break protection should use capacitor-specific fuses, and the rated current should be selected according to 1.43 ~ 1.5 times of the rated current of the capacitor.
8. When the capacitor is directly connected in parallel with the high-voltage motor, in order to prevent self-excitation when the motor is disconnected from the power
supply, causing the voltage at the capacitor terminal to rise above the rated value, the rated current of the capacitor must be less than 90% of the no-load current of the
motor; When the motor uses Y / wiring, it is not allowed to connect the capacitor directly to the motor, and special wiring should be adopted.
9. When the capacitor is used at an altitude higher than 1000 meters or the capacitor is used in a humid tropical zone, it should be specified when ordering.
10. When there are special specifications or special requirements for capacitors, they should be explained when ordering

 
Polymer housed for outdoor application
60kv Capacators
Features
Better Electrical performance & reliability
Ease of Installation-Light weight & smaller size
Better Operating conditions
Explosion & shatter proof & less mechanical
damage to nearby equipments
Better performance in polluted environment
Vandalism resistant
Free from Moisture ingress
Higher safety
Higher mechanical strength
Insensitive to UV radiation
High resistance to Ozone & Corona
Excellent Tracking resistance
Performance Data
System Voltage
Rated Voltage (kV):0.1-275
Nominal discharge current (kA)
High current capability (4/10us) kA
Energy Class :
Energy absorption Capability kJ/kV
Short Circuit (Pressure relief) kA:40
Standard in accordance with:IEC60099-4
Porcelain housed for outdoor application

 
For protection of transformer & switchgear.
Highly non-linear MOV.
Explosion Proof - Pressure Relief Design.
High energy handling capacity.
Glazed brown Porcelain Housing.
Corrosion proof Aluminum alloy metal flange.
Suitable for Ambient -400C to +550C.
manufactures effective surge protection device with the modern technology of highly non-linear Zinc
Oxide Varistor blocks and thus diverts natural lightning surge and switching surge to earth and simultaneously clip off
any follow on current. Our station class arresters are designed to provide maximum safety to personnel and sub-station
equipment even at the enormous short circuit duty. Research and Development is an ongoing process at Elektrolites
with the active collaboration of experts in the industry.
CONSTRUCTION & OPERATING PRINCIPLE
60kv Capacators
 
 Lightning Arrestors
 
11kV
 
 
 
No. DETAIL UNITS DATA

 
Type
 
11kV gapless type metal oxide surge
arrester - Distribution class
1. Nominal  system  voltage kV 11
2. Highest system voltage kV 12
3. Basic Insulation Leve(BIL) kV 95

 
 
3.   Ratings and type of surge arrester

 

 
4. Specification to which surge arrester complies
 
IEC
60099-4
5. Rated voltage of surge arrester kV 10
6. Nominal, 8/20 µs, discharge current rating of
surge arrester
kA 10
7. Maximum continuous operating voltage of
surge arrester
kV 7.3
8. Gapless or gapped type metal-oxide surge
arrester

 
Gapless
9. Material of insulation
 
High temperature vulcanised silicon
rubber
10. Rated frequency of surge arrester Hz 50
11. Design altitude of surge arrester (above sea
level)
m 1 400m
12. Design ambient temperature of surge arrester oC -1 to40
13. Specific creepage distance of surge arrester .mm/kV 25

 
Automatic earth lead disconnectors
requirements

 

 
14. Automatic earth lead disconnectors to be fitted Yes/No YES
 

 
 
15. Corrosion protection of metal and alloy parts:
galvanising specification and/or stainless steel grade

 
To SABS 763, 316

 
Tests
 

 
16. Previous type test results/certificate to be
provided with bid
Yes/No Yes
17. Routine test results/certificate to be provided
on delivery
Yes/No Yes
18. Drawing showing dimensions of the arrestor to
be provided with the bid
Yes/No Yes
19. Minimum one minute wet power frequency
withstand voltage of external insulation of surge arrester housing
kV 28
20. Maximum steep current impulse residual
voltage for a 10 kA, 1/20 µs, discharge current
kV 50
21. Maximum lightning impulse residual voltage
for a 10 kA, 8/20 µs, discharge current
kV 40
22. Lightning, 1,2/50 µs, impulse withstand level
of external insulation of surge arrester housing
kV 95
23. Line discharge class rating
 
1
24. Long duration current, 2 000 µs, impulse
withstand
A 250 A
25. High current, 4/10 µs, impulse withstand kA 100 kA
26. Automatic earth lead disconnector to be tested
in accordance with IEC 60099-4
Yes/No Yes
 
 
 
 
 
 
 
 
 
 
 
33kV
 
 
 
 
S/N TECHNICAL DETAILS UNITS DATA
1. Type
 
33kV gapless type metal
oxide surge arrester -
Distribution class
2. Nominal  system  voltage kV 33
3. Highest system voltage kV 36
4. Power frequency Hz 50
5. Basic Insulation Leve(BIL) kV 170

 
 
3.   Ratings and type of surge arrester

 

 
6. Specification to which surge arrester complies
 
IEC 60099
7. Rated voltage of surge arrester kV 29
8. Nominal, 8/20 µs, discharge current rating of surge arrester kA 10
9. Maximum continuous operating voltage of surge arrester kV 22
10. Gapless or gapped type metal-oxide surge arrester
 
Gapless
11. Insulation Material
 
Silicon rubber
12. Cantilever strength of surge arrester Nm 300
13. Rated frequency of surge arrester Hz 50
14. Design altitude of surge arrester (above sea level) m 1 400m
15. Design ambient temperature of surge arrester oC -1 to 40
16. Minimum phase-to-ground specific creepage distance of
surge arrester
.mm/kV 25

 
Automatic earth lead disconnectors requirements
 

 
17. Automatic earth lead disconnectors fitted Yes/No Yes
18. Corrosion protection of metal and alloy parts: galvanising
 
To  SABS 763, 316

 

 

 

 

 
 

 
 

 
specification and/or stainless steel grade
 

 

 
Tests
 

 
19. Previous Type Test reports/certificate  from recognized
authority to be provided with bid
Yes/No Yes
20. Minimum one minute wet power frequency withstand
voltage of external insulation of surge arrester housing
kV 70
21. Maximum steep current impulse residual voltage for a 10
kA, 1/20 µs, discharge current
kV 99.7
22. Maximum lightning impulse residual voltage for a 10 kA,
8/20 µs, discharge current
kV 91.8
23. Lightning, 1,2/50 µs, impulse withstand level of external
insulation of surge arrester housing
kV 170
24. Line discharge class rating Class 1
25. Long duration current, 2 000 µs, impulse withstand A 250 A
26. High current, 4/10 µs, impulse withstand kA 100 kA
27. Is the automatic earth lead disconnector tested in accordance
with IEC 60099-4?
Yes/No Yes
 
 
 
 
66kV
 
 
 
 
S/N TECHNICAL DETAILS UNITS DATA
1. Description
 
Station type lightning arrestor
complete with steel support structures.
2. Type
 
Zinc oxide gapless lightning
arrestor

 
System parameters
 

 
3. Nominal  system  voltage kV 66
4. Highest system voltage kV 72.5
5. Power frequency Hz 50
6. Type of system earthing
 
Effective/Non effective
7. Type of arrestor connection to system
 
Line to ground

 
 
3.   Ratings and type of surge arrester

 

 
8. Rated voltage of surge arrester kV rms 54
9. Nominal, 8/20 µs, discharge current rating of surge arrester kA peak 10
10. Maximum continuous operating voltage of surge arrester kV 43
11. Minimum one minute wet power frequency withstand voltage kVrms 140
 
 
151
 
 
 
 

 
of external insulation of surge arrester housing
 

 
12. Maximum steep current impulse residual voltage for a 2 kA,
30/60 µs, discharge current
kVpeak 104
13. Maximum lightning impulse residual voltage for a 10 kA, 8/20
µs, discharge current
kVpeak 127
14. Minimum lightning, 1,2/50 µs, impulse withstand level of
external insulation of surge arrester housing

 
325
15. Line discharge class rating
 
2
16. Lighting arrestor counter, leakage current meter and their
accessories to be provided
Yes/No Yes
17. Gapless or gapped type metal-oxide surge arrester
 
Gapless
18. Insulation Material
 
Porcelain
19. Cantilever strength of surge arrester Nm 3000
20. Rated frequency of surge arrester Hz 50
21. Maximum angle from vertical at which surge arrester is fully
functional
Deg 45
22. Design altitude of surge arrester (above sea level) m 1400 m
23. Design ambient temperature of surge arrester oC -1 to 40
24. Humidity % 85
25. Specific phase-to-ground creepage of surge arrester .mm/kV 25
26. Corrosion protection of metal and alloy parts: galvanising
specification and/or stainless steel grade

 
to SABS 763 or 316 stainless
steel
27. Previous type test results/certificate to be provided with bid Yes/No Yes
28. Design drawings showing dimensions including foundations
and brochures to be provided with bid
Yes/No Yes
29. Quality Assurance certification to be provided with the bid Yes/No Yes
30. Routine test results/certificate to be provided on delivery Yes/No Yes
31. Galvanized steel support structures complete with bolts &
washers to be provided on delivery
Yes/No Yes
32. Applicable standard
 
IEC60099
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
152

 
 
 
 
88Kv
 
 
 
 
S/N TECHNICAL DETAILS UNITS DATA
33. Description
 
Station type lightning arrestor
complete with steel support structures.
34. Type
 
Zinc oxide gapless lightning
arrestor

 
System parameters
 

 
35. Nominasystem  voltage kV 88
36. Highest system voltage kV 100
37. Power frequency Hz 50
38. Type of system earthing
 
Effective/Non effective
39. Type of arrestor connection to system
 
Line to ground

 
 
3.   Ratings and type of surge arrester

 

 
40. Rated voltage of surge arrester kV rms 84
41. Nominal, 8/20 µs, discharge current rating of surge arrester kA peak 10
42. Maximum continuous operating voltage of surge arrester kV 67
43. Minimum one minute wet power frequency withstand voltage
of external insulation of surge arrester housing
kVrms 185

 
Maximum steep current impulse residual voltage for a 2 kA, kVpeak 188

 
30/60 µs, discharge current
 

 
45. Maximum lightning impulse residual voltage for a 10 kA, 8/20
µs, discharge current
kVpeak 218
46. Minimum lightning, 1,2/50 µs, impulse withstand level of
external insulation of surge arrester housing

 
450
47. Line discharge class rating
 
2
48. Lighting arrestor counter, leakage current meter and their
accessories to be provided
Yes/No Yes
49. Gapless or gapped type metal-oxide surge arrester
 
Gapless
50. Insulation Material
 
Porcelain
51. Cantilever strength of surge arrester Nm 3000
52. Rated frequency of surge arrester Hz 50
53. Maximum angle from vertical at which surge arrester is fully
functional
Deg 45
54. Design altitude of surge arrester (above sea level) m 1400 m
55. Design ambient temperature of surge arrester oC -1 to 40
56. Humidity % 85
57. Specific phase-to-ground creepage of surge arrester .mm/kV 25
58. Corrosion protection of metal and alloy parts: galvanising
specification and/or stainless steel grade

 
to SABS 763 or 316 stainless
steel
59. Previous type test results/certificate to be provided with bid Yes/No Yes
60. Design drawings showing dimensions including foundations
and brochures to be provided with bid
Yes/No Yes
61. Quality Assurance certification to be provided with the bid Yes/No Yes
62. Routine test results/certificate to be provided on delivery Yes/No Yes
63. Galvanized steel support structures complete with bolts &
washers to be provided on delivery
Yes/No Yes
64. Applicable standard
 
IEC60099
 
 
 
 
 
 
 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
Management System Certification
OHSAS18001:2007, ISO 9001: 2015 Certificate, ISO 14001:2015 Certificate