Drop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut out

Product Details
Customization: Available
Breaking Capacity: High
Type: Distribution
Still deciding? Get samples of $ !
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
OHSAS18001:2007, ISO 9001: 2015 Certificate, ISO 14001:2015 Certificate
  • Drop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut out
  • Drop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut out
  • Drop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut out
  • Drop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut out
  • Drop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut out
  • Drop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut out
Find Similar Products

Basic Info.

Model NO.
PRW-
Usage
High Voltage
Shape
Circle
Fusing Speed
T K
Fusing Device
Fuse Link
Standard
IEC IEEE
Function
Over-Current Protection
Fuse Base Material
Porcelain
Application
Distribution Line
Rated Current
100A, 200A
Transport Package
Carton, Pallet
Specification
48.5*34.5*10.5
Trademark
oeipower
Origin
China

Packaging & Delivery

Package Size
60.00cm * 50.00cm * 15.00cm
Package Gross Weight
6.000kg

Product Description



Drop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut out
Drop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut outDrop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut outDrop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut outDrop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut outDrop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut outDrop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut outDrop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut outDrop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut outDrop-out Outdoor High Voltage Expulsion Dropout Fuse Cutout 12kv 100A Cut outDROP OUT FUSES
11Kv
 
 
 
N/O DETAIL   DATA
1 Description   11kV Fuse link assembly complete with
fuse carrier rated at 100A and mounting bracket to PIESA 002. (See Figure 1  to Figure 12 below)
2 System conditions of service
 
 
 
a) nominal Voltage (Un) r.m.s
 
 
 
 
kV
 
 
 
 
11
b) maximum system voltage (Um) r.m.s KV 12
c) earthing   Effective & non effective
d) Frequency Hz 50
3 Site conditions of service
a) altitude
 
m
 
1400
b) Operating Ambient temperature °C -1 to 40
c) Humidity % 85
4 Rating    
a) Nominal voltage kV 11
b) Rated current Fuse carrier  
A
 
100
 
Cut out base
 
A
 
200
5 Electrical components    
a) Insulator material specification   Porcelain
Dielectric strength    
Lightning  impulse withstand (1.2/50) kV 95
Power frequency wet withstand voltage
r.m.s
kV 28
6 Specific creepage distance mm/kV 25
7 General information to be provided
with bid:
   
 

 
 
  Drawings and brochures showing
outline and general arrangement
 
Yes/No
 
Yes
  b) Detailed drawings of all items
showing critical tolerances to be provided with bid
Yes/No Yes
8 Previous Type test report/certificate on
complete fuse link assembly to be provided with bid
 
Yes/No
 
Yes
10 Routine tests (acceptance tests on
sample
Product) to be provided on delivery
Yes/No Yes
11 Applicable standard   PIESA 002
12 Other applicable standards   NRS 035
SABS IEC 60282-2
SABS IEC 60186
BS 137 part 2
 
 
 

3.   FURTHER REQUIREMENTS:
 
3.1 There shall be no rivets in the parts that form the current path
3.2 Water shall not be able to accumulate on any part of the equipment nor shall any feature introduce moisture into any component.
3.3 The design shall incorporate all reasonable precautions and provisions for the safety of personnel concerned with the operation and maintenance of the same.
3.4 The  current  path  shall  be  such  that  load  current  shall  only  flow  through  high conductive materials such as copper and its alloys. Load current shall not be permitted to flow through ferrous components, springs, or spring-loaded mechanisms.
3.5 All load current paths shall be so designed that the relevant parts of the solid link assembly are capable of carrying the specified rated current without exceeding the permitted temperature rise in SABS IEC 60282-2
3.6 Contacts shall be based on the line contact principle and there shall be no welds on the contact parts. The construction of the Drop out fuse base and the solid link shall ensure their mutual alignment during closure.
3.7 The solid link should have an eye and an operating tongue.
 
4.   MARKING AND IDENTIFICATION
 
4.1 Markings to conform to SABS IEC 60282-2
4.2 In addition , the following markings must  be included : ZESCO Indent No.
 
3.0   SUPPLIMENTARY NOTES
 
3.3 Suppliers should give sufficient information including drawings (which must be brief, clear and to the point) on how their drop out fuse designs addresses these requirements. Further, Suppliers may offer better alternatives that are of cost benefits to. It is therefore imperative that schedule "B" is completed by the tenderer. Any deviations/modifications/alternatives specification must be listed in schedule "C."  No deviations/modifications/alternatives will be recognised unless they are listed in schedule "C"
3.4 The drawings to be submitted by the tenderer must include the following:
 
3.4.1    Critical tolerances
3.4.2    Show details of the insulator, the fuse carrier, the solid-link, the upper contact, the lower contact, the cutout base and the bracket for fixing to either wooden or steel cross arm.
 
3.5 The type tests to be submitted must be those issued by internationally recognised testing authority.
3.6  All salient design details of each item required shall be supplied with the tender.
33kV
 
 
 
 
 
 
 
 
N/ O DETAIL   DATA
1 Description   33 kV Fuse link assembly complete with fuse carrier rated at 100A and mounting bracket to PIESA 002. (See Figure 1  to
Figure 12 below)
2 System conditions of service
 
 
 
a) nominal Voltage (Un) r.m.s
 
 
 
 
kV
 
 
 
 
33
b) maximum system voltage (Um)
r.m.s
KV 36
c) earthing   Effective & non effective
d) Frequency Hz 50
3 Site conditions of service a) altitude  
m
 
1400
b) Operating Ambient temperature °C -1 to 40
c) Humidity % 85
4 Rating    
a) Nominal voltage kV 33
b) Rated current Fuse carrier  
 
 
A
 
 
 
100
 
Cut out base
 
A
 
200
5 Electrical components    
a) Insulator material specification   Porcelain
Dielectric strength    
Lightning impulse withstand
(1.2/50)
kV 170
Power frequency wet withstand voltage r.m.s kV 70
6 Specific creepage distance mm/kV 25
 

 
 
7 General information to be provided with bid:
Drawings and brochures showing outline and general arrangement
 
 
 
 
Yes/No
 
 
 
 
Yes
  b) Detailed drawings of all items showing critical tolerances to be
provided with bid
Yes/No Yes
8 Previous Type test report/certificate on complete fuse link assembly to
be provided with bid
 
Yes/No
 
Yes
10 Routine tests (acceptance tests on sample
Product) to be provided on delivery
Yes/No Yes
11 Applicable standard   PIESA 002
12 Other applicable standards   NRS 035
SABS IEC 60282-2
SABS IEC 60186
BS 137 part 2


5. FURTHER REQUIREMENTS:
 
5.1 There shall be no rivets in the parts that form the current path
5.2 Water shall not be able to accumulate on any part of the equipment nor shall any feature introduce moisture into any component.
5.3 The design shall incorporate all reasonable precautions and provisions for the safety of personnel concerned with the operation and maintenance of the
same.
5.4 The current path shall be such that load current shall only flow through high conductive materials such as copper and its alloys. Load current shall not be permitted to flow through ferrous components, springs, or spring-loaded mechanisms.
5.5 All load current paths shall be so designed that the relevant parts of the solid link assembly are capable of carrying the specified rated current without exceeding the permitted temperature rise in SABS IEC 60282-2
5.6 Contacts shall be based on the line contact principle and there shall be no welds on the contact parts. The construction of the Drop out fuse base and the solid link shall ensure their mutual alignment during closure.
5.7 The solid link should have an eye and an operating tongue.
 
6. MARKING AND IDENTIFICATION
 
6.1 Markings to conform to SABS IEC 60282-2
 
3.0 SUPPLIMENTARY NOTES
 
3.5 Suppliers should give sufficient information including drawings (which must
be brief, clear and to the point) on how their drop out fuse designs addresses these requirements. Further, Suppliers may offer better alternatives that are of cost benefits
3.6 The drawings to be submitted by the tenderer must include the following:
 
3.6.1  Critical tolerances
3.6.2  Show details of the insulator, the fuse carrier, the solid-link, the
upper contact, the lower contact, the cutout base and the bracket for fixing to either wooden or steel cross arm.
 