Lug, Alum. 2 Hole Canton 394.5mcm

Product Details
Customization: Available
Type: Distribution
Structure: Zinc Oxide Arrester
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
OHSAS18001:2007, ISO 9001: 2015 Certificate, ISO 14001:2015 Certificate
  • Lug, Alum. 2 Hole Canton 394.5mcm
  • Lug, Alum. 2 Hole Canton 394.5mcm
  • Lug, Alum. 2 Hole Canton 394.5mcm
  • Lug, Alum. 2 Hole Canton 394.5mcm
  • Lug, Alum. 2 Hole Canton 394.5mcm
  • Lug, Alum. 2 Hole Canton 394.5mcm
Find Similar Products

Basic Info.

Installation
Pole Line
Application
AC/DC System
Size
Meidum
Operation Voltage
High Voltage
Shape
Round
Material
ZnO
Certification
Xihari
Brand
Oeipower Jingguan
12
Kv
24
Kv
36
Kv
Transport Package
Cartons Pallets Wooden Case
Specification
IEC IEEE
Trademark
OEIpower
Origin
China Nanyang
HS Code
85354000
Production Capacity
100000

Product Description

Lug, Alum. 2 Hole Canton 394.5mcmLug, Alum. 2 Hole Canton 394.5mcmLug, Alum. 2 Hole Canton 394.5mcmLug, Alum. 2 Hole Canton 394.5mcmLug, Alum. 2 Hole Canton 394.5mcmLug, Alum. 2 Hole Canton 394.5mcm

Item
#

AL/Cu    Conductor
Dimension
Color
Code

Die   Index

Wire
Strip
Length

Temp. Rating

Stud
Size

(K)
No.
of
Holes
in
Pad

(OD)

(B)

( C)

(L)

(N)

(E)

(T)
36 400 kcmil
½

0.56
2 1.19 2.26 1.62 6.15 0.63 1.75 0.43 Green 472 2
90oC
61 1/0 AWG 1 0.60 1.05 1.03 2.83
0.63
- 0.17 Tan 296 1- 1/16
62 2 1.11 1.85 1.52 6.07 1.75 0.39 Brown 299 2- 1/8
63 4/0 str. 0.85 1.39 1.17 5.19 0.30 White 298 1-5/8
105 1 -

    Must be used on both aluminum and copper conductors.
    Connectors must be clearly marked with wire size, die index, color code, and crimp location bands
    Must pre-filled with oxide inhibitor
    Must have color coded end caps are factory inserted in the barrels to match the die
color code and prevent foreign materials from entering the barrel.
    Must accommodate conductor types:
o  Aluminum Code Wire: Class B (Concentric, Compressed, Compact)
o  Copper Code Wire: Class B (Concentric, Compressed, Compact or Class C
o  Copper Clad Aluminum: Noted in the conductor accommodates as CCA


Application field
The surge arresters protect the network and their
equipment from overvoltages. They are of key importance
to improve the quality and reliability of the power supply.
 
 
 Design
Our surge arresters fulfil the requirements of
IEC60099-4.
 
Operating conditions
Ambient temperature : - 50°C up to + 50°C

 
Technical parameters
• Rated voltage Ur : 3 kV up to 36 kV
• Nominal discharge current : 10 kA
• High current impulse withstand : 100 kA
• Long duration current impulse withstand : 300 A
• Line discharge class : 1
• Short circuit withstand : 20 kA / 0,2 s
 
 Type  Unit HE 03 HE05 HE06 HE09 HE10 HE12 HE12/ R HE15 HE18 HE 18 /R HE21 HE24 HE24
/R
HE24
/2R
HE27 HE30 HE33 HE36 HE36
/ R
Rated voltage  kV eff
/ rms
3,3 5 6 9 10 12 12 15 18 18 21 24 24 24 27 30 33 36 36
Continuous operating voltage  kV eff
/ rms
2,8 4.25 5.1 7.65 8.4 10.2 10.2 12.7 15.3 15,3 17.5 20.0 20.0 20.0 22.5 25 27.5 30 30
 maximale Maximum residual voltage
5 kA 8/20
10kA 8/20
20kA 8/20
kV 
/ peak
15.4
16.4
18.1
14.3
15.2
16.8
15.4
16.4
18.1
26.4
28.1
31.1
27.5
29.3
32.4
30.8
32.8
36.2
30.8
32.8
36.2
40.7
43.3
47.8
46.2
49.1
54.3
46,2
49,1
54,3
56.1
59.7
66.0
61.2
65.1
71.9
61.2
65.1
71.9
61.2
65.1
71.9
72.2
76.8
84.9
76.2
81.1
89.6
87.2
92.8
102.5
91.7
97.5
107.5
91.7
97.5
107.7

Switching residual voltage at 500- 30/80
kV 
/ peak
8,0 12.1 13.0 22.3 23.3 26.1 26.1 34.4 39.0 39,0 47.5 51.8 51.8 51.8 61.1 64.5 73.8 77.5 77.5

Steep current impulse residual voltage at 10kA-1/2.5
kV  peak 10,8 16.4 17.7 30.3 31.6 35.4 35.4 46.8 53.0 53,0 64.5 70.3 70.3 70.3 82.9 87.6 100.2 105.3 105.3

Lighning impulse withstand level of the housing
kV 1.2/50 95 110 125 170 200 170 200
Flexion dynamique (SSL) / Specified short-term load
Flexion statique (SLL) / Specified long-term load
N.m 125
100
250
200
125
100
250
200
Creepage distance mm 480 650 800 1200 1360 1200 1360
Height mm 165 205 245 325 365 325 365
Diameter mm 104 109 114
Weight (S3D2 option) kg 1,4 1.5 1.5 1.7 1.7 1.7 1.9 2.1 2.1 2,3 2.5 2.5 2.9 3.1 3.1 3.1 3,3 3,3 3,5
 
Option
NO option: supplied with bolts, washers, and
clamp for connection
IF option: electronic fault indicator using a red
flag for easy signalling
S3D2 option*: ground lead disconnector and
insulating bracket

 
 
 
Accessories
Metal bracket for horizontal or vertical mounting
Flexible earth lead
Pedestal (insulated or not)
 
 
Disconnecting device S3D2 type
 
 
The disconnecting device (S3D2) separates
automatically the bottom terminal of the failed
arrester from earth
It provides a visual indication of the failure
It gives priority to continuity of service
The disconnector is not a fault clearing device
 
 
 
 
 
 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier